Guide for Authors

  • All journal information and instructions compiled in one document (PDF) in just one mouse-click Author information pack

    INTRODUCTION
    • Contact details for submission
    BEFORE YOU BEGIN
    • Ethics in publishing
    • Conflict of interest
    • Submission declaration and verification
    • Changes to authorship
    • Copyright
    • Role of the funding source
    • Funding body agreements and policies
    • Open access
    • Language (usage and editing services)
    • Submission
    PREPARATION
    • NEW SUBMISSIONS
    • References
    • Formatting requirements
    • REVISED SUBMISSIONS
    • Article structure
    • Essential title page information
    • Abstract
    • Graphical abstract
    • Highlights
    • Keywords
    • Acknowledgements
    • Nomenclature and Units
    • Math Formulae
    • Footnotes
    • References
    • Video data
    • AudioSlides
    • Supplementary data
    • Interactive plots
    • Submission checklist
    AFTER ACCEPTANCE
    • Use of the Digital Object Identifier
    • Online proof correction
    • Offprints
    • Appendix A. Brief recommendations for reporting thermal analysis data
    AUTHOR INQUIRIES

    Your Paper Your Way
    your paper your way



    Thermochimica Acta publishes original research contributions covering all aspects of thermoanalytical and calorimetric methods and their application to experimental chemistry, physics, biology and engineering. Specific areas of research include:
    - instrumentation and theory of instrumentation
    - new and improved methods of investigation
    - analysis and interpretation of research data
    - fundamental research and industrial application.
    Papers from new emerging areas of the field are particularly welcome. The journal publishes regular articles, communications (novel, unexpected experimental results or interpretation presented within four printed pages), and feature articles (usually invited by the Editors).

    Important announcement regarding submission of manuscripts reporting experimental results Click here
    For information on the NIST collaboration, please read the editorial TCA Editorial.

    Contact details for submission

    Editors of Thermochimica Acta A

    N. Koga
    Dept. of Science Education
    Graduate School of Education
    Hiroshima University
    1-1-1 Kagamiyama
    739-8524, Higashi-Hiroshima City
    Japan
    Tel/Fax: +81-82-424-7092 E-mail: nkoga@hiroshima-u.ac.jp

    Prof. C. Schick
    Universität Rostock
    FB Physik
    Universitätsplatz 3
    18051 Rostock, Germany
    Tel: +49 381 498 1644;
    fax: +49 381 498 1626
    E-mail: christoph.schick@physik.uni-rostock.de

    Prof. S. Vyazovkin
    Department of Chemistry
    University of Alabama at Birmingham
    901 S. 14th Street
    Birmingham, AL 35294, USA
    Tel.: +1 205 975 9410;
    fax: +1 205 934 2543
    E-mail: vyazovkin@uab.edu

    Ethics in publishing

    For information on Ethics in publishing and Ethical guidelines for journal publication see http://www.elsevier.com/publishingethics and http://www.elsevier.com/journal-authors/ethics.

    Conflict of interest

    All authors are requested to disclose any actual or potential conflict of interest including any financial, personal or other relationships with other people or organizations within three years of beginning the submitted work that could inappropriately influence, or be perceived to influence, their work. See also http://www.elsevier.com/conflictsofinterest. Further information and an example of a Conflict of Interest form can be found at: http://help.elsevier.com/app/answers/detail/a_id/286/p/7923.

    Submission declaration and verification

    Submission of an article implies that the work described has not been published previously (except in the form of an abstract or as part of a published lecture or academic thesis or as an electronic preprint, see http://www.elsevier.com/postingpolicy), that it is not under consideration for publication elsewhere, that its publication is approved by all authors and tacitly or explicitly by the responsible authorities where the work was carried out, and that, if accepted, it will not be published elsewhere in the same form, in English or in any other language, including electronically without the written consent of the copyright-holder. To verify originality, your article may be checked by the originality detection service CrossCheck http://www.elsevier.com/editors/plagdetect.

    Changes to authorship

    This policy concerns the addition, deletion, or rearrangement of author names in the authorship of accepted manuscripts:
    Before the accepted manuscript is published in an online issue: Requests to add or remove an author, or to rearrange the author names, must be sent to the Journal Manager from the corresponding author of the accepted manuscript and must include: (a) the reason the name should be added or removed, or the author names rearranged and (b) written confirmation (e-mail, fax, letter) from all authors that they agree with the addition, removal or rearrangement. In the case of addition or removal of authors, this includes confirmation from the author being added or removed. Requests that are not sent by the corresponding author will be forwarded by the Journal Manager to the corresponding author, who must follow the procedure as described above. Note that: (1) Journal Managers will inform the Journal Editors of any such requests and (2) publication of the accepted manuscript in an online issue is suspended until authorship has been agreed.
    After the accepted manuscript is published in an online issue: Any requests to add, delete, or rearrange author names in an article published in an online issue will follow the same policies as noted above and result in a corrigendum.

    Copyright

    This journal offers authors a choice in publishing their research: Open access and Subscription.

    For subscription articles
    Upon acceptance of an article, authors will be asked to complete a 'Journal Publishing Agreement' (for more information on this and copyright, see http://www.elsevier.com/copyright). An e-mail will be sent to the corresponding author confirming receipt of the manuscript together with a 'Journal Publishing Agreement' form or a link to the online version of this agreement.
    Subscribers may reproduce tables of contents or prepare lists of articles including abstracts for internal circulation within their institutions. Permission of the Publisher is required for resale or distribution outside the institution and for all other derivative works, including compilations and translations (please consult http://www.elsevier.com/permissions). If excerpts from other copyrighted works are included, the author(s) must obtain written permission from the copyright owners and credit the source(s) in the article. Elsevier has preprinted forms for use by authors in these cases: please consult http://www.elsevier.com/permissions.

    For open access articles
    Upon acceptance of an article, authors will be asked to complete an 'Exclusive License Agreement' (for more information see http://www.elsevier.com/OAauthoragreement). Permitted reuse of open access articles is determined by the author's choice of user license (see http://www.elsevier.com/openaccesslicenses).

    Retained author rights
    As an author you (or your employer or institution) retain certain rights. For more information on author rights for:
    Subscription articles please see http://www.elsevier.com/journal-authors/author-rights-and-responsibilities.
    Open access articles please see http://www.elsevier.com/OAauthoragreement.

    Role of the funding source

    You are requested to identify who provided financial support for the conduct of the research and/or preparation of the article and to briefly describe the role of the sponsor(s), if any, in study design; in the collection, analysis and interpretation of data; in the writing of the report; and in the decision to submit the article for publication. If the funding source(s) had no such involvement then this should be stated.

    Funding body agreements and policies

    Elsevier has established agreements and developed policies to allow authors whose articles appear in journals published by Elsevier, to comply with potential manuscript archiving requirements as specified as conditions of their grant awards. To learn more about existing agreements and policies please visit http://www.elsevier.com/fundingbodies.

    Open access

    This journal offers authors a choice in publishing their research:

    Open access
    • Articles are freely available to both subscribers and the wider public with permitted reuse
    • An open access publication fee is payable by authors or their research funder
    Subscription
    • Articles are made available to subscribers as well as developing countries and patient groups through our access programs (http://www.elsevier.com/access)
    • No open access publication fee

    All articles published open access will be immediately and permanently free for everyone to read and download. Permitted reuse is defined by your choice of one of the following Creative Commons user licenses:
    Creative Commons Attribution (CC BY): lets others distribute and copy the article, to create extracts, abstracts, and other revised versions, adaptations or derivative works of or from an article (such as a translation), to include in a collective work (such as an anthology), to text or data mine the article, even for commercial purposes, as long as they credit the author(s), do not represent the author as endorsing their adaptation of the article, and do not modify the article in such a way as to damage the author's honor or reputation.
    Creative Commons Attribution-NonCommercial-ShareAlike (CC BY-NC-SA): for non-commercial purposes, lets others distribute and copy the article, to create extracts, abstracts and other revised versions, adaptations or derivative works of or from an article (such as a translation), to include in a collective work (such as an anthology), to text and data mine the article, as long as they credit the author(s), do not represent the author as endorsing their adaptation of the article, do not modify the article in such a way as to damage the author's honor or reputation, and license their new adaptations or creations under identical terms (CC BY-NC-SA).
    Creative Commons Attribution-NonCommercial-NoDerivs (CC BY-NC-ND): for non-commercial purposes, lets others distribute and copy the article, and to include in a collective work (such as an anthology), as long as they credit the author(s) and provided they do not alter or modify the article.

    To provide open access, this journal has a publication fee which needs to be met by the authors or their research funders for each article published open access.
    Your publication choice will have no effect on the peer review process or acceptance of submitted articles.

    The publication fee for this journal is $2600, excluding taxes. Learn more about Elsevier's pricing policy: http://www.elsevier.com/openaccesspricing.

    Language (usage and editing services)

    Please write your text in good English (American or British usage is accepted, but not a mixture of these). Authors who feel their English language manuscript may require editing to eliminate possible grammatical or spelling errors and to conform to correct scientific English may wish to use the English Language Editing service available from Elsevier's WebShop (http://webshop.elsevier.com/languageediting/) or visit our customer support site (http://support.elsevier.com) for more information.

    Submission

    Submission to this journal proceeds totally online and you will be guided stepwise through the creation and uploading of your files. The system automatically converts source files to a single PDF file of the article, which is used in the peer-review process. Please note that even though manuscript source files are converted to PDF files at submission for the review process, these source files are needed for further processing after acceptance. All correspondence, including notification of the Editor's decision and requests for revision, takes place by e-mail removing the need for a paper trail.

    NEW SUBMISSIONS

    Submission to this journal proceeds totally online and you will be guided stepwise through the creation and uploading of your files. The system automatically converts your files to a single PDF file, which is used in the peer-review process.
    As part of the Your Paper Your Way service, you may choose to submit your manuscript as a single file to be used in the refereeing process. This can be a PDF file or a Word document, in any format or lay-out that can be used by referees to evaluate your manuscript. It should contain high enough quality figures for refereeing. If you prefer to do so, you may still provide all or some of the source files at the initial submission. Please note that individual figure files larger than 10 MB must be uploaded separately.

    References

    There are no strict requirements on reference formatting at submission. References can be in any style or format as long as the style is consistent. Where applicable, author(s) name(s), journal title/book title, chapter title/article title, year of publication, volume number/book chapter and the pagination must be present. Use of DOI is highly encouraged. The reference style used by the journal will be applied to the accepted article by Elsevier at the proof stage. Note that missing data will be highlighted at proof stage for the author to correct.

    Formatting requirements

    There are no strict formatting requirements but all manuscripts must contain the essential elements needed to convey your manuscript, for example Abstract, Keywords, Introduction, Materials and Methods, Results, Conclusions, Artwork and Tables with Captions.
    If your article includes any Videos and/or other Supplementary material, this should be included in your initial submission for peer review purposes.
    Divide the article into clearly defined sections.

    Please ensure your paper has consecutive line numbering – this is an essential peer review requirement.

    Figures and tables embedded in text
    Please ensure the figures and the tables included in the single file are placed next to the relevant text in the manuscript, rather than at the bottom or the top of the file.

    REVISED SUBMISSIONS

    Use of word processing software
    Regardless of the file format of the original submission, at revision you must provide us with an editable file of the entire article. Keep the layout of the text as simple as possible. Most formatting codes will be removed and replaced on processing the article. The electronic text should be prepared in a way very similar to that of conventional manuscripts (see also the Guide to Publishing with Elsevier: http://www.elsevier.com/guidepublication). See also the section on Electronic artwork.
    To avoid unnecessary errors you are strongly advised to use the 'spell-check' and 'grammar-check' functions of your word processor.

    Article structure

    Subdivision - numbered sections
    Divide your article into clearly defined and numbered sections. Subsections should be numbered 1.1 (then 1.1.1, 1.1.2, ...), 1.2, etc. (the abstract is not included in section numbering). Use this numbering also for internal cross-referencing: do not just refer to 'the text'. Any subsection may be given a brief heading. Each heading should appear on its own separate line.

    Introduction
    State the objectives of the work and provide an adequate background, avoiding a detailed literature survey or a summary of the results.

    For full-length manuscripts, a proper introduction is required. The purpose of the introduction is to briefly summarise previous work and recent progress in the field and not to repeat information found in previous publications. The introduction must be kept to a minimum length and only references that pertain to the information in the manuscript should be used. For shorter articles, introductions should be correspondingly brief.

    Theory/calculation
    A Theory section should extend, not repeat, the background to the article already dealt with in the Introduction and lay the foundation for further work. In contrast, a Calculation section represents a practical development from a theoretical basis.

    Manuscripts reporting results of kinetic studies are expected to follow the ICTAC Kinetics Committee recommendations for collecting kinetic data; published in Thermochim. Acta 590 (2014) 1-23 and for performing kinetic computations (Thermochim. Acta 520 (2011) 1-19).
    Include in figure legends and table texts technical details of methods used, while describing the methods themselves in the main text.

    Discussion
    This should explore the significance of the results of the work, not repeat them. A combined Results and Discussion section is often appropriate. Avoid extensive citations and discussion of published literature.

    Conclusions
    The main conclusions of the study may be presented in a short Conclusions section, which may stand alone or form a subsection of a Discussion or Results and Discussion section.

    Appendices
    If there is more than one appendix, they should be identified as A, B, etc. Formulae and equations in appendices should be given separate numbering: Eq. (A.1), Eq. (A.2), etc.; in a subsequent appendix, Eq. (B.1) and so on. Similarly for tables and figures: Table A.1; Fig. A.1, etc.

    Essential title page information

    Title. Concise and informative. Titles are often used in information-retrieval systems. Avoid abbreviations and formulae where possible.
    Author names and affiliations. Where the family name may be ambiguous (e.g., a double name), please indicate this clearly. Present the authors' affiliation addresses (where the actual work was done) below the names. Indicate all affiliations with a lower-case superscript letter immediately after the author's name and in front of the appropriate address. Provide the full postal address of each affiliation, including the country name and, if available, the e-mail address of each author.
    Corresponding author. Clearly indicate who will handle correspondence at all stages of refereeing and publication, also post-publication. Ensure that phone numbers (with country and area code) are provided in addition to the e-mail address and the complete postal address. Contact details must be kept up to date by the corresponding author.
    Present/permanent address. If an author has moved since the work described in the article was done, or was visiting at the time, a 'Present address' (or 'Permanent address') may be indicated as a footnote to that author's name. The address at which the author actually did the work must be retained as the main, affiliation address. Superscript Arabic numerals are used for such footnotes.

    Abstract

    A concise and factual abstract of approximately 100-150words identifying the new and significant results of the study must be provided for all manuscripts, including articles, reviews, and communications. The abstract should comprise a brief and factual account of the contents and conclusions of the paper as well as an indication of any new information presented and its relevance. An abstract is often presented separately from the article, so it must be able to stand alone. For this reason, References should be avoided, but if essential, then cite the author(s) and year(s). Also, non-standard or uncommon abbreviations should be avoided, but if essential they must be defined at their first mention in the abstract itself.

    Graphical abstract

    A Graphical abstract is optional and should summarize the contents of the article in a concise, pictorial form designed to capture the attention of a wide readership online. Authors must provide images that clearly represent the work described in the article. Graphical abstracts should be submitted as a separate file in the online submission system. Image size: Please provide an image with a minimum of 531 × 1328 pixels (h × w) or proportionally more. The image should be readable at a size of 5 × 13 cm using a regular screen resolution of 96 dpi. Preferred file types: TIFF, EPS, PDF or MS Office files. See http://www.elsevier.com/graphicalabstracts for examples.
    Authors can make use of Elsevier's Illustration and Enhancement service to ensure the best presentation of their images also in accordance with all technical requirements: Illustration Service.

    Highlights

    Highlights are mandatory for this journal. They consist of a short collection of bullet points that convey the core findings of the article and should be submitted in a separate file in the online submission system. Please use 'Highlights' in the file name and include 3 to 5 bullet points (maximum 85 characters, including spaces, per bullet point). See http://www.elsevier.com/highlights for examples.

    Keywords

    Immediately after the abstract, provide a maximum of 6 keywords, using American spelling and avoiding general and plural terms and multiple concepts (avoid, for example, 'and', 'of'). Be sparing with abbreviations: only abbreviations firmly established in the field may be eligible. These keywords will be used for indexing purposes.

    Acknowledgements

    Collate acknowledgements in a separate section at the end of the article before the references and do not, therefore, include them on the title page, as a footnote to the title or otherwise. List here those individuals who provided help during the research (e.g., providing language help, writing assistance or proof reading the article, etc.).

    Nomenclature and Units

    Nomenclature: Nomenclature should conform to current scientific usage. Author(s) should use systematic names similar to those used by Chemical Abstracts Service and the International Union of Pure and Applied Chemistry. Chemical Abstracts (CA) nomenclature rules can be found in Appendix IV of the Chemical Abstracts Index Guide

    Math Formulae

    Maths: Detailed mathematical discussion should be placed in an appendix. Equations and formulae should be typewritten. Present simple formulae in the line of normal text where possible. Variables are to be presented in italics. Use the solidus (/) instead of a horizontal line, e.g., Xp/Ym. Powers of e are often more conveniently denoted by exp. Number consecutively any equations that have to be displayed separate from the text (if referred to explicitly in the text).

    Footnotes

    Footnotes should be used sparingly. Number them consecutively throughout the article. Many wordprocessors build footnotes into the text, and this feature may be used. Should this not be the case, indicate the position of footnotes in the text and present the footnotes themselves separately at the end of the article. Do not include footnotes in the Reference list.
    Table footnotes
    Indicate each footnote in a table with a superscript lowercase letter.

    Electronic artwork
    General points
    • Make sure you use uniform lettering and sizing of your original artwork.
    • Preferred fonts: Arial (or Helvetica), Times New Roman (or Times), Symbol, Courier.
    • Number the illustrations according to their sequence in the text.
    • Use a logical naming convention for your artwork files.
    • Indicate per figure if it is a single, 1.5 or 2-column fitting image.
    • For Word submissions only, you may still provide figures and their captions, and tables within a single file at the revision stage.
    • Please note that individual figure files larger than 10 MB must be provided in separate source files.
    A detailed guide on electronic artwork is available on our website:
    http://www.elsevier.com/artworkinstructions.
    You are urged to visit this site; some excerpts from the detailed information are given here.
    Formats
    Regardless of the application used, when your electronic artwork is finalized, please 'save as' or convert the images to one of the following formats (note the resolution requirements for line drawings, halftones, and line/halftone combinations given below):
    EPS (or PDF): Vector drawings. Embed the font or save the text as 'graphics'.
    TIFF (or JPG): Color or grayscale photographs (halftones): always use a minimum of 300 dpi.
    TIFF (or JPG): Bitmapped line drawings: use a minimum of 1000 dpi.
    TIFF (or JPG): Combinations bitmapped line/half-tone (color or grayscale): a minimum of 500 dpi is required.
    Please do not:
    • Supply files that are optimized for screen use (e.g., GIF, BMP, PICT, WPG); the resolution is too low.
    • Supply files that are too low in resolution.
    • Submit graphics that are disproportionately large for the content.

    Figure captions
    Ensure that each illustration has a caption. A caption should comprise a brief title (not on the figure itself) and a description of the illustration. Keep text in the illustrations themselves to a minimum but explain all symbols and abbreviations used.

    References

    Citation in text
    Please ensure that every reference cited in the text is also present in the reference list (and vice versa). Any references cited in the abstract must be given in full. Unpublished results and personal communications are not recommended in the reference list, but may be mentioned in the text. If these references are included in the reference list they should follow the standard reference style of the journal and should include a substitution of the publication date with either 'Unpublished results' or 'Personal communication'. Citation of a reference as 'in press' implies that the item has been accepted for publication.

    Reference links
    Increased discoverability of research and high quality peer review are ensured by online links to the sources cited. In order to allow us to create links to abstracting and indexing services, such as Scopus, CrossRef and PubMed, please ensure that data provided in the references are correct. Please note that incorrect surnames, journal/book titles, publication year and pagination may prevent link creation. When copying references, please be careful as they may already contain errors. Use of the DOI is encouraged.

    Web references
    As a minimum, the full URL should be given and the date when the reference was last accessed. Any further information, if known (DOI, author names, dates, reference to a source publication, etc.), should also be given. Web references can be listed separately (e.g., after the reference list) under a different heading if desired, or can be included in the reference list.

    Reference management software
    This journal has standard templates available in key reference management packages EndNote (http://www.endnote.com/support/enstyles.asp) and Reference Manager (http://refman.com/support/rmstyles.asp). Using plug-ins to wordprocessing packages, authors only need to select the appropriate journal template when preparing their article and the list of references and citations to these will be formatted according to the journal style which is described below.

    Reference formatting
    There are no strict requirements on reference formatting at submission. References can be in any style or format as long as the style is consistent. Where applicable, author(s) name(s), journal title/book title, chapter title/article title, year of publication, volume number/book chapter and the pagination must be present. Use of DOI is highly encouraged. The reference style used by the journal will be applied to the accepted article by Elsevier at the proof stage. Note that missing data will be highlighted at proof stage for the author to correct. If you do wish to format the references yourself they should be arranged according to the following examples:

    Reference style
    Text: Indicate references by number(s) in square brackets in line with the text. The actual authors can be referred to, but the reference number(s) must always be given.
    Example: '..... as demonstrated [3,6]. Barnaby and Jones [8] obtained a different result ....'
    List: Number the references (numbers in square brackets) in the list in the order in which they appear in the text.
    Examples:
    Reference to a journal publication:
    [1] J. van der Geer, J.A.J. Hanraads, R.A. Lupton, The art of writing a scientific article, J. Sci. Commun. 163 (2010) 51–59.
    Reference to a book:
    [2] W. Strunk Jr., E.B. White, The Elements of Style, fourth ed., Longman, New York, 2000.
    Reference to a chapter in an edited book:
    [3] G.R. Mettam, L.B. Adams, How to prepare an electronic version of your article, in: B.S. Jones, R.Z. Smith (Eds.), Introduction to the Electronic Age, E-Publishing Inc., New York, 2009, pp. 281–304.

    Journal abbreviations source
    Journal names should be abbreviated according to the List of Title Word Abbreviations: http://www.issn.org/services/online-services/access-to-the-ltwa/.

    Video data

    Elsevier accepts video material and animation sequences to support and enhance your scientific research. Authors who have video or animation files that they wish to submit with their article are strongly encouraged to include links to these within the body of the article. This can be done in the same way as a figure or table by referring to the video or animation content and noting in the body text where it should be placed. All submitted files should be properly labeled so that they directly relate to the video file's content. In order to ensure that your video or animation material is directly usable, please provide the files in one of our recommended file formats with a preferred maximum size of 50 MB. Video and animation files supplied will be published online in the electronic version of your article in Elsevier Web products, including ScienceDirect: http://www.sciencedirect.com. Please supply 'stills' with your files: you can choose any frame from the video or animation or make a separate image. These will be used instead of standard icons and will personalize the link to your video data. For more detailed instructions please visit our video instruction pages at http://www.elsevier.com/artworkinstructions. Note: since video and animation cannot be embedded in the print version of the journal, please provide text for both the electronic and the print version for the portions of the article that refer to this content.

    AudioSlides

    The journal encourages authors to create an AudioSlides presentation with their published article. AudioSlides are brief, webinar-style presentations that are shown next to the online article on ScienceDirect. This gives authors the opportunity to summarize their research in their own words and to help readers understand what the paper is about. More information and examples are available at http://www.elsevier.com/audioslides. Authors of this journal will automatically receive an invitation e-mail to create an AudioSlides presentation after acceptance of their paper.

    Supplementary data

    Elsevier accepts electronic supplementary material to support and enhance your scientific research. Supplementary files offer the author additional possibilities to publish supporting applications, high-resolution images, background datasets, sound clips and more. Supplementary files supplied will be published online alongside the electronic version of your article in Elsevier Web products, including ScienceDirect: http://www.sciencedirect.com. In order to ensure that your submitted material is directly usable, please provide the data in one of our recommended file formats. Authors should submit the material in electronic format together with the article and supply a concise and descriptive caption for each file. For more detailed instructions please visit our artwork instruction pages at http://www.elsevier.com/artworkinstructions.

    Interactive plots

    This journal encourages you to include data and quantitative results as interactive plots with your publication. To make use of this feature, please include your data as a CSV (comma-separated values) file when you submit your manuscript. Please refer to http://www.elsevier.com/interactiveplots for further details and formatting instructions.

    Submission checklist

    The following list will be useful during the final checking of an article prior to sending it to the journal for review. Please consult this Guide for Authors for further details of any item.
    Ensure that the following items are present:
    One author has been designated as the corresponding author with contact details:
    • E-mail address
    • Full postal address
    • Telephone
    All necessary files have been uploaded, and contain:
    • Keywords
    • All figure captions
    • All tables (including title, description, footnotes)
    Further considerations
    • Manuscript has been 'spell-checked' and 'grammar-checked'
    • All references mentioned in the Reference list are cited in the text, and vice versa
    • Permission has been obtained for use of copyrighted material from other sources (including the Web)
    • Color figures are clearly marked as being intended for color reproduction on the Web (free of charge) and in print, or to be reproduced in color on the Web (free of charge) and in black-and-white in print
    • If only color on the Web is required, black-and-white versions of the figures are also supplied for printing purposes
    For any further information please visit our customer support site at http://support.elsevier.com.

    Use of the Digital Object Identifier

    The Digital Object Identifier (DOI) may be used to cite and link to electronic documents. The DOI consists of a unique alpha-numeric character string which is assigned to a document by the publisher upon the initial electronic publication. The assigned DOI never changes. Therefore, it is an ideal medium for citing a document, particularly 'Articles in press' because they have not yet received their full bibliographic information. Example of a correctly given DOI (in URL format; here an article in the journal Physics Letters B):
    http://dx.doi.org/10.1016/j.physletb.2010.09.059
    When you use a DOI to create links to documents on the web, the DOIs are guaranteed never to change.

    Online proof correction

    Corresponding authors will receive an e-mail with a link to our online proofing system, allowing annotation and correction of proofs online. The environment is similar to MS Word: in addition to editing text, you can also comment on figures/tables and answer questions from the Copy Editor. Web-based proofing provides a faster and less error-prone process by allowing you to directly type your corrections, eliminating the potential introduction of errors.
    If preferred, you can still choose to annotate and upload your edits on the PDF version. All instructions for proofing will be given in the e-mail we send to authors, including alternative methods to the online version and PDF.
    We will do everything possible to get your article published quickly and accurately - please upload all of your corrections within 48 hours. It is important to ensure that all corrections are sent back to us in one communication. Please check carefully before replying, as inclusion of any subsequent corrections cannot be guaranteed. Proofreading is solely your responsibility. Note that Elsevier may proceed with the publication of your article if no response is received.

    Offprints

    The corresponding author, at no cost, will be provided with a personalized link providing 50 days free access to the final published version of the article on ScienceDirect. This link can also be used for sharing via email and social networks. For an extra charge, paper offprints can be ordered via the offprint order form which is sent once the article is accepted for publication. Both corresponding and co-authors may order offprints at any time via Elsevier's WebShop (http://webshop.elsevier.com/myarticleservices/offprints). Authors requiring printed copies of multiple articles may use Elsevier WebShop's 'Create Your Own Book' service to collate multiple articles within a single cover (http://webshop.elsevier.com/myarticleservices/booklets).

    Appendix A. Brief recommendations for reporting thermal analysis data

    Because thermal analysis techniques involve the measurement of some system parameter as a function of temperature [1], it is essential that all experimental details be given in the typescript. The reports of the Nomenclature Committee of the International Confederation for Thermal Analysis (ICTA) [2,3] and the recommendations of McAdie [4,5] should, in general, be adhered to as far as typescript space permits. Some of the recommendations are briefly summarized here; for further information the original references should be consulted.
    (1) Identify all materials by a definitive name, an empirical formula, or equivalent compositional data.
    (2) State the sources of all materials, their chemical purities, and other pertinent data.
    (3) Give the furnace heating rate over the temperature range of interest.
    (4) Identify the sample chamber atmosphere by pressure, composition and purity. The conditions of atmosphere control (static, dynamic or self-generated) should be specified.
    (5) Label the abscissa in temperature units or time.

    In reporting TG data:

    (6) Give the type of thermobalance employed, including the manufacturer's name and the instrument model number.
    (7) Mass loss should be plotted as a downward type curve either in mass or percent mass units.

    In reporting DTA data:

    (8) Give the type of instrument employed, including the manufacturer's name and the instrument model number.
    (9) Report the sample preparation and dilution, and also the reference material employed.
    (10) The ordinate scale should indicate the temperature difference between sample and reference sample T = TS-TR. Preferred plotting for endothermic reactions consists of downward deflection of the curve peaks, and exothermic reactions as upward deflections. In addition, authors must make clear the sign convention they are using.

    In reporting DSC data:

    (11) Give the type of instrument employed, including the manufacturer's name and the instrument model number.
    (12) The ordinate scale should be described in power or units. Plotting for endothermic reactions is as upward deflection of the curve peaks, and exothermic reactions as downward deflections. In addition, authors must make clear the sign convention they are using.

    Other thermal analysis techniques:

    (13) Give the type of instrument employed, including the manufacturer's name and the instrument model number.
    (14) The ordinate scale should be accurately described in the preferred units of measurement.
    Quantities and units
    Length l: metre (m)
    Mass m: kilogram (kg); gram (g)
    Time t: second (s); minute (min); hour (h)
    Thermodynamic temperature T; kelvin (K)
    Celsius temperature t: degree Celsius (°C)
    Amount of substance n: mole (mol)
    Molar mass M: (kg mol¯1)
    Concentration (amount) c: (mol dm¯3); (mol l¯l)
    Molality m: (mol kg¯1)
    Pressure p: pascal (Pa)
    Energy E: joule (J)
    Heat q, Q: joule (J)
    Power, heat flow rate P, Ф: watt (W)
    Volume V: (m3); litre (1), (L)
    Chemical potential (partial molar Gibbs energy): (_J mol¯1)
    Viscosity: dynamic &eegr; (Pa s); kinematic (_ms¯1)
    Subscripts to denote a chemical process:
    Combustion: c; reaction: r; transition: trs; fusion: fus; solution: sol; vaporization: vap; mixing: mix; sublimation: sub.
    Superscripts for standard conditions
    _ or °
    Examples: p_ = 105 Pa (1 bar)
    DcH_
    HBH_ (standard partial molar enthalpy of substance B)


    Prefixes
    10¯1 d; 10¯2 c (centi); 10¯3 m (milli); 10¯6 _ (micro); 10¯9 n
    (nano); 10¯12 p (pico); 10¯15 f (femto); 10¯18 a (atta); 10 da (deca); 102 h (hecto); 103 k (kilo); 106M (mega); 109 G (giga);
    1012 T (tera); 1015 P (peta); 1018 E (exa)
    Special recommendations for thermal analysis
    (International Confederation for Thermal Analysis and Calorimetry, ICTAC)
    Differential scanning calorimetry: DSC
    Differential thermal analysis: DTA
    Dynamic mechanical analysis: DMA
    Thermogravimetry/thermogravimetric analysis: TG/TGA
    Thermomechanical analysis: TMA
    Average heating rate: beta (K min—1)
    Fractional extent of reaction: alpha
    Subscripts
    S, sample; R, reference sample.
    To denote characteristic temperatures: i, initial; e, extrapolated onset; p, peak; f, final, g, glass transition.
    When labelling the axes of graphs, symbols and units must be used as follows in order to have dimensionless data on the axes.
    Examples
    T/K or Tin K
    (or temperature in K)
    103 T/K
    m/kg or m in kg
    (or mass in kg)
    ln (p/MPa)
    P/Wor P in W
    (or heat flow rate in W)
    do not write T(K) or T[K], etc.

    References
    [1] W.W. Wendlandt, Thermal Methods of Analysis, third ed., Wiley-Interscience, New York, 1976, Chapter 1.
    [2] R.C. Mackenzie, Talanta 16 (1969) 1227.
    [3] R.C. Mackenzie, C.J. Keattch, D. Dollimore, J.A. Forrester, A.A. Hodgson, J.P. Redfern, Talanta 19 (1972) 1079.
    [4] H.G. McAdie, Anal. Chem. 39 (1967) 543.
    [5] H.G. McAdie, Anal. Chem. 44 (1972) 640.



    You can track your submitted article at http://help.elsevier.com/app/answers/detail/a_id/89/p/8045/. You can track your accepted article at http://www.elsevier.com/trackarticle. You are also welcome to contact Customer Support via http://support.elsevier.com.

Advertisement

advert image